Errores Sinoboom Eléctricas: Cómo Diagnosticar

Sinoboom Electric Scissor Lift Error Codes: How to Diagnose

Error Codes and Solutions

Below you will find a complete guide to the most common error codes for aerial platforms, with a description of the problem, operational limitations, and solutions.

Alarm Codes and Limitations

Code Problem Limitation Solution
OL Overload Disable movements Remove the excess weight immediately.
LL Machine out of level Disable up and down Restore level or check sensor wiring.
FT Pedal failure, man present Disables PCU controls Check the pedal microswitch on the joystick.
CL Micro anti-collision alarm Disable up and down Check the operation of the micro anti-collision system.
SL Sleep Mode Disable everything Press a button or reset to exit.
ID Indoor Mode Information Actual height for indoor use only.
OH Altura Outdoor Disable upload Maximum height reached for outdoor use.
CH Chassis Information Key turned to ground controls.

System Error Codes

Code Problem Solution
01 System initialization failure ECU malfunction; replace.
02 Communication failure Check PCU/ECU communication and power cables.
03 Incorrect configuration Select the correct machine settings.
04/09 Calibration error / Communication Recalibrate system or check angle/pressure sensors.
18 Error Spondine Pothole Check mini-skirt openings and microswitches.
20-29 Battery and BMS Errors Notify BMS factory; check voltages and temperatures.
36/37 Low battery / Off Charge battery or use joystick to exit sleep mode.
46/47 Joystick not at zero / Pushbuttons Ensure neutral position; verify neutral zone parameters.
52-59 Coil (Valve) Errors Check connections, for cut or shorted coils.
60-75 Motor Controller (MC) Errors Check engines, cool if overheating, or replace MC.
80/90/99 Load warnings Load close to the limit (80%, 90% or 99%).

Problem Solving (Troubleshooting)

  • The power light does not turn on: Check if the emergency stop button is pressed or if the key is in the center position.
  • Invalid platform operations: Verify that the key is in the "Platform" position and that the system has been reset after an update.
  • The platform does not rise to the maximum (Indoor): Recalibrate the height or adjust the travel switch.
  • Forward/backward movement not working: Check PWM connectors of the proportional solenoid valve on the carriage.

Important Notes

  • For any error code, always consult the manufacturer's manual.
  • If the problem persists after applying the solution, contact technical support.
  • Keep a record of error codes to facilitate preventative maintenance.